Efficient-networks Siemens Sinamics S120 User Manual Page 49

  • Download
  • Add to my manuals
  • Print
  • Page
    / 560
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 48
Extended setpoint channel
2.3 Jog
Drive Functions
Function Manual, (FH1), 07/2007 Edition, 6SL3097-2AB00-0BP4
49
Jog
Field bus
Setpoint via PROFIBUS, for example
Via the analog inputs of the following exemplary components:
e.g. Terminal Board 30 (TB30)
e.g. Terminal Module 31 (TM31)
e.g. Terminal Module 41 (TM41)
2.3 Jog
Description
This function can be selected via digital inputs or via a field bus (e.g. PROFIBUS). The
setpoint is, therefore, predefined via p1058[D] and p1059[D].
When a jog signal is present, the motor is accelerated to the jog setpoint with the
acceleration ramp of the ramp-function generator (referred to the maximum speed p1082;
see diagram "Function chart: jog 1 and jog 2"). After the jog signal has been deselected, the
motor is decelerated via the set ramp of the ramp-function generator.
CAUTION
The jog function is not PROFIdrive compatible!
6LJQDO
-RJ
6LJQDO
212))
7RWDOVHWSRLQW
HIIHFWLYHU
-RJVHWSRLQW
$FWLYH
Figure 2-2 Function chart: jog and OFF1
Page view 48
1 2 ... 44 45 46 47 48 49 50 51 52 53 54 ... 559 560

Comments to this Manuals

No comments